72´´ X .250´´ SMS DEMAG TENSION LEVEL SECTION, YEAR 2009 (NEW - NEVER USED)

Sold

Specifications

ManufacturerSMS-Demag
ConditionNew
Stock NumberVX-10148
Strip thickness.060" Minimum, .250" Maximum
Bridle rolls42" Diameter
Material flowEither Right to Left or Left of Right per SMS
Design speed300 FPM
Electrical supply460/3/60
Air supply80 psi
Number of pre-flex rolls2
Pre-flex roll diameter44.5 mm HRc 64/62
Anti-cross bow roll diameter76.2 mm (1.752") HRc 64/62
Back up roll (multiples) diameter74 mm (2.913") (HRc 58/56 (crowned)
NotesMotors come complete with blower motors and starters.
Number of tension rolls5
Number of snubber rolls3
Diameter42"
SurfacePolyurethane
Tension roll driveVariable Speed Electric
Snubber roll driveVariable Speed Electric

Description

Material Data: Strip Width: 24" - 74" Line Data: Line Speed: 20 - 300 FPM Elongation Rate: 5% @ .110" x 48" x 86,000 psi Yield Strength 75% @ .060" x 60" x 80,000 psi Yield Strength 75% @ .060" x 72" x 70,000 psi Yield Strength 50% @ .070" x 72" x 60,000 psi Yield Strength 3% @ .080" x 66" x 50,000 psi Yield Strength 25% @ .140" x 72" x 50,000 psi Yield Strength 5% @ .170" x 72" x 40,000 psi Yield Strength 80% @ .250" x 72" x 40,000 psi Yield Strength Roll Change-out is via cartridge injector systems on rails on drive side of bridle rolls, via hydraulic motor and chain drives. Bridle roll diameters are identical for all five entry and five exit rolls: 1,050 mm (41.339") (Polyurethane jacketed) The separate Anti-Coil Break Roll stand has a work roll diameter of 130 mm (5.119") with two backup rolls of 180 mm (7.087") diameter and a separately actuated hold-down roll with 406 mm (15.984") diameter. AC Variable Speed Motors (Preliminary): Bridle Roll No. 1, 30 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM, 100% Brake Bridle Roll No. 2, 40 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 3, 100 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 4, 150 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 5, 150 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 6, 275 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 7, 300 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 8, 175 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM, 100% Brake Bridle Roll No. 9, 75 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Bridle Roll No. 10, 60 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Entry Snubber Roll (3), 25 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Exit Snubber Roll (3), 40 HP, TEFC Enclosure, 460 Volts, 1750/1950 RPM Incoming 3 Phase Supply All drives have full regeneration capabilities to the common DC buss. With a common DC buss, the energy produced by a regenerating drive, ie: entry bridle drives during line run can be used to power the exit bridle drives thereby significantly reducing the incoming power requirement from the three phase supply. Drive regeneration is used during an Emergency Stop to quickly stop the strip so snubber resistors are supplied to dissipate the excess energy. One AC Drive isolation transformer is included for the new AC Drives. Entry Five Roll Tension Bridle Unit: Tension Rolls: Snubber Rolls: Diameter: 10" Surface: Polyurethane